Portable Multiparameter Turbidity and Ion Specific Meter
Model: HI93102
Manufacturer: Hanna Instruments
The HI93102 is a portable multiparameter meter that measures turbidity, free and total chlorine, cyanuric acid, pH, iodine, bromine, and low range iron. This meter combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the turbidity after calibration with AMCO-AEPA-1 standards; determination of free chlorine, total chlorine, cyanuric acid, pH, iodine, bromine, and low range iron is reliable and consistent with the use of ready made reagents.
Portable Multiparameter Turbidity and Ion Specific Meter
Model: HI93102
Manufacturer: Hanna Instruments
Description:
ALL IN 1 MULTI-FUNCTION MEASUREMENT DEVICE
To measure turbidity, no reagents are needed.
For bromine, chlorine, cyanuric acid, iodine, iron, and pH, simply purchase the reagents for the specific parameter being measured.
TURBIDITY CALIBRATION
HI93102 turbidity calibration at 2 points at 0 and 20 NTU (standard solutions sold separately)
GLP
Review the information and the last calibration date
LOCKING SYSTEM ON THE CUVET COVER AND ENGINE
There is a mark on the measuring chamber of the instrument and on the cuvette lid, ensuring that the cuvettes are inserted into the measuring chamber in the same position each time a measurement is taken.
DATA RECORDING
Record up to 25 measured values. Recordings can be easily reviewed with a single button press, and an alert will appear if the memory is full. Recording mode can be enabled or disabled.
ERROR WARNING
On-screen messages warn of issues such as missing caps, high zeros, or excessively low calibration, helping to avoid measurement errors caused by mistakes
Technical Data:
|
pH |
|
|
Scale |
5.9 to 8.5 pH |
|
Resolution |
0.1 pH |
|
Accuracy |
± 0.1 pH |
|
Reagents |
|
|
Turbidity |
|
|
Scale |
0.00 to 50.0 NTU |
|
Resolution |
0.01 (0.00 to 9.99); 0.1 NTU (10.0 to 50.0) |
|
Accuracy |
±0.5 NTU or ±5% of the measured result |
|
Calibration |
2 points, 0.00 and 20.0 FTU |
|
Calibration solution |
HI93102-0: 0 NTU HI93102-20: 20 NTU |
|
Residual chlorine and total chlorine |
|
|
Scale |
Residual Chlorine: 0.00 to 2.50 mg/L (ppm) Cl 2 Total Chlorine: 0.00 to 3.50 mg/L (ppm) Cl2 |
|
Resolution |
0.01 mg/L |
|
Accuracy |
±0.03 mg/L ±3% of the measured result |
|
Reagents |
Residual chlorine: HI93701-01 Total chlorine: HI93711-01 |
|
Axit Cyanuric |
|
|
Scale |
0 to 80 mg/L (ppm) |
|
Resolution |
1 mg/L |
|
Accuracy |
±1 mg/L ±15% of the measured result |
|
Reagents |
|
|
Iot |
|
|
Scale |
0.0 to 12.5 mg/L (ppm) I 2 |
|
Resolution |
0.1 mg/L |
|
Accuracy |
±0.1 mg/L ±5% of the measured result |
|
Reagents |
|
|
Brom |
|
|
Scale |
0.00 to 8.00 mg/L (ppm) Br 2 |
|
Resolution |
0.01 mg/L |
|
Accuracy |
±0.08 mg/L ±3% of the measured result |
|
Reagents |
|
|
Low iron ladder |
|
|
Scale |
0.00 to 1.00 mg/L (ppm) Fe |
|
Resolution |
0.01 mg/L |
|
Accuracy |
±0.02 mg/L ±3% of the measured result |
|
Method |
TPTZ |
|
Reagents |
|
|
Measuring instrument specifications |
|
|
Light source |
LED @525nm |
|
Record data |
Up to 25 copies |
|
Automatic Shutdown |
after 10 minutes in measurement mode; after 1 hour in calibration mode since the last measurement. |
|
Environment |
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
|
Pin |
4 x 1.5V |
|
Size |
220 x 82 x 66 mm |
|
Mass |
510 g |
|
Guarantee |
12 months (For products with intact seals and original warranty cards) |
|
The supply includes: |
- HI93102 multimeter with battery - 2 cuvettes with caps - Warranty card (warranty is void without warranty card) - Quality certificate for the measuring instrument - User manual - Paper box Turbidity calibration solution and reagents are sold separately. |